Long term standardised measurement, observation, evaluation and reporting of the quality of surface waters started in the 1950's in Hungary. The evolution of the monitoring network of surface water quality is illustrated in Table 1. The number of sampling sites has decreased appreciably, accompanied, however, by an increase in sampling frequency.
| Year | Number of sampling sites | Number of samples per year |
| 1954 | 1400 | 1 |
| 1956-1959 | 800 | 4 |
| 1960-1967 | 800 | 2-112 |
| 1968-1984 | 300 | 12-26-52 |
| 1985-1993 | 250 | 12-26-52 |
| 1994- | 150 | 12-26-52 |
Table 1. Historic development of the water quality monitoring network in Hungary.
The monitoring network, (operated by both the environmental and public health authorities) is required to perform the following functions:
The standard sampling stations of the surface water quality monitoring network are situated:
Other important considerations in selecting sampling sites were:
Sampling points are normally located in the stream's centreline or in the line of the main current.
The factors involved in deciding upon the frequency of sampling were:
The samples are analysed for its chemical and hydrobiological components in laboratories of the 12 District Environmental Inspectorates. These laboratories are technically not able to analyse all the monitored micro-pollutants. Specific organic micropollutants are mainly analysed in appropriately equipped central laboratories. Microbiological parameters are measured by the Public Health Laboratories of the country's 20 counties. The applied analytical methods are also regulated by the MSZ 12749 Standard. Special attention is paid to quality assurance of the analytical work of the laboratories by running an inter-calibration programme.
The measured data are sent from the laboratories to the Institute for Environmental Management (KGI). The data is sent on diskette generally at monthly intervals. The collected data is checked and stored with the national database. "VM" is a software that was developed to process the database. VM provides statistical evaluation of the data in accordance with the classification system under MSZ 12749.
The water quality monitoring data system is an integral part of the complex information network that includes water quality and hydrology.
| Countries | Austria- Hungary | Slovakia- Hungary | Ukraine- Hungary | Romania- Hungary | Yugoslavia- Hungary* | Croatia- Hungary* | Slovenia- Hungary* |
|---|---|---|---|---|---|---|---|
| Number of sampling sites | 11+8**=19 | 10+1x3**=33 | 2 | 7 | 3 | 3 | 1 |
| Sampling procedure | In odd months: Austrian sampling In even months: Hungarian sampling |
Joint sampling | Joint: 4 Ukrainian: 4 Hungarian: 4 |
Romanian: 12 Hungarian: 12 |
Joint: 4 Yugoslavian: 4 Hungarian: 4 |
Joint: 4 Croatian: 4 Hungarian: 4 |
Joint: 4 Slovenian: 4 Hungarian: 4 |
| Sampling frequency (per year) | 12 | 12 | 12 | 24 | 12 | 12 | 12 |
| Frequency of analysis (per year) | Usually: 12 Special components: 6 |
Usually: 12 Special components: 6 |
12 | 24 | 12 | Usually: 12 Special components: 4 |
Usually: 12 Special components: 4 |
| Laboratory site of analysis | Odd months: Austria Even months: Hungary |
Slovakia: 12 analysis Hungary: 12 analysis |
Ukraine: 8 Hungary: 8 |
Romania: 12 Hungary : 12 |
Yugoslavia: 8 Hungary: 8 |
Croatia: 8 Hungary: 8 |
Slovenia: 8 Hungary: 8 |
| Number of yearly data agreement meetings | 1 | 2 | 1 | Results accepted without data agreement meeting | 1 | 1 | 1 |
| Data exchange | Direct exchange of hard copy data | Direct exchange of hard copy data | Direct exchange of hard copy data | Data exchange by fax | Direct exchange of hard copy data | Direct exchange of hard copy data | Direct exchange of hard copy data |
| Evaluation method for the measured data | Statistical parameters biannually | Statistical parameters biannually | Statistical parameters for every year | Statistical parameters for every year | Statistical parameters for every year | - | - |
| Trend analysis | Once in 10 years | Once in 5 years | - | Once in 5 years | - | - | - |
| Spreadsheet software | EXCEL 5.0 | EXCEL 5.0 | - | EXCEL 5.0 | - | - | - |
| Water quality criteria | National standards | CMEA system (six classes, 1984) | CMEA system (three classes, 1963) | - | CMEA system (three classes, 1963) | CMEA system (three classes, 1963) | CMEA system (three classes, 1963) |
| Frequency of inter-laboratory calibration | One per 12 samples | - | One per 12 samples | One per 12 samples | - | - | - |
Table 2. Water quality monitoring of transboundary waters. Details of cooperative monitoring practices.
VITUKI (1995) Development of Surface Water Monitoring Based on EU Practice in Hungary. PHARE Project W-905/90. Project Report. VITUKI, Budapest.